ME2T-PRO-II 144/28MHz Transverter measurements

RX Measurements: ( by HG5AZB laboratory)
                              
meas equipments: R&S SMU200/A, R&S FSIQ3, Anritsu MS2661C, MS2668C

Front end: PGA-103+
IF mixer: HJK-3H+
HJK-3H+  14MHz IF measurements( pdf)
HJK-3H+  28MHz IF measurements( pdf)
Gain: 25dB
LO: 116MHz    +23dBm

RX OIP3 > +35dBm
RX IP3  +10dBm


RX noise figure measurement ( overall)


RX OIP3/50KHz


 

RX OIP3/ 20KHz


RX OIP3/ 2KHz


OIP3= +36dBm

Min. discernible Input Signal (in case TS590S cw BW=500Hz        -146dBm

Max. spurious free Input Signal                                                 - 40.7dBm

Spurious free dynamic range                                                     105.3dB

 




 

 

 

 

 

 

 

 

 

TX Measurements

TX output signal ( Transverter unit)



 

TX Harmonics measurements

TX IM3 Measurements

TCXO PHASE NOISE

PDI +/-1ppm

AXTAL +/-0.5ppm

AXTAL TCXO stability measurements.